Danfoss’ Flow Sensor Series is designed to protect
personnel and property in case of hose failure in
compliance with Federal Safety Regulations. Flow Sensors
are intended for use with compressed air.
FS Flow Sensor Series
Product Features
• Automatically shuts off air flow to
ruptured hose
• Automatically resets after failure
correction
• Compact design, economical, tamperresistant
• Reduces risk of injury or damage from
hose whip
• Operates in any orientation
• Standard body material: Brass
Physical Characteristics
Max. Operating Pressure
Min. Burst Pressure
Rated Flow
Size
(bar)
(psi)
(bar)
(psi)
(lpm)
(gpm)
All Sizes
17
250
68
1,000
See Chart
See Chart
Applications & Markets
• General Industry
• Pneumatic Tools
Flow Data
80
Minimum Inlet Pressure Drop, psi
70
B4-FS-25F-2
B6-FS-37F-5
B8-FS-50F-8
B12-FS-75F-13
B16-FS-100F-21
B24-FS-150F-45
Hose LENGTH,
Length, feetfeet
HOSE
Flow Data: The graph above indicates the minimum inlet pressure for various hose
lengths. Each Flow Sensor has a shut-o昀昀 昀氀ow rating dependent upon inlet pressure.
The length of hose and 昀椀tting size are critical in the proper operation of the valve. For
example, with the B8FS50F8 Flow Sensor, the hose I.D. must be 1/2” using only 1/2” pipe
thread end 昀椀ttings. Thirty feet of hose requires at least 20 psig inlet pressure; 昀椀fty feet of
hose requires at least 28 psig inlet pressure; and seventy-昀椀ve feet of hose requires at
least 36 psig inlet pressure. Inlet pressures lower than those indicated on the curves
above will not guarantee protection in case of hose failure. Valve shut-o昀昀 occurs only
when flow exceeds the flow rating for the inlet pressure.
If hose lengths greater than 75 feet are required, a 1/2” size or larger Flow Sensor must be
installed on the inlet end of each 75-foot section, and a correspondingly higher inlet
pressure must be supplied for proper operation of the Flow Sensor to assure safety.
Part
Number*
Body
Size
Thread
Size
Type
Shut-off Flow, SCFM, at Inlet Pressure, PSIG
60
80
100
120
140
160
180
200
Dimensions
Length
Hex
Length
Hex
(in)
(mm)
(mm)
(in)
B4FS25F2
1/4
1/4-18
NPTF
16
18
20
22
23
25
26
27
2.14
0.75
54.36
19.05
B6FS37F5
3/8
3/8-18
NPTF
41
46
50
55
59
63
66
69
2.50
0.88
63.50
22.35
B8FS50F8
1/2
1/2-14
NPTF
65
73
80
87
93
99
704
109
3.12
1.06
79.25
26.92
B12FS75F13
3/4
3/4-14
NPTF
105
118
130
141
152
161
169
177
3.68
1.38
93.47
35.05
B16FS100F21
1
1-11 1/2
NPTF
170
191
210
227
245
260
273
286
4.59
1.75
116.59
44.45
B24FS150F45
1 1/2
1 1/2-11 1/2
NPTF
365
410
450
489
525
557
586
615
5.86
2.50
148.84
63.50
*All flow sensors have a pressure drop of approximately 2 psid at 80% of shut-off flow