Quick Disconnect Couplings - Flipbook - Seite 256
Operation and Service Info
Operation
FLOCS 30A
Air-powered Unit
1.
2.
Piston pump
5 cfm air-operated motor
(80-150 psi)
The FLOCS 30A unit is
a simple self-controlled
automatic oil evacuator.
Once it has been started it
will operate until all the oil
has been evacuated from
the oil pan. The unit will stop
automatically when air enters
the suction hose.
6.
Coupling half**
7.
Suction strainer
8.
Override button
1/4" air-supply coupling
3.
9.
4.
Cycle gauge
1/4" air-supply nipple
15' of 1" I.D. suction hose*
10. 1" NPT discharge port
5.
Specifications
• Flow rate: see flow chart.
• Maximum discharge
pressure: 1/5 of the input air
pressure (power source).
• Pump power source:
80 to 150 psi air at 5
CFM minimum.
• Recommended operating
temperature of fluid: +60ºF. to
180ºF.
• Strainer screen size: size
35 mesh.
• Fluid handling compatibility:
all petroleum base fluids below
6000 SSU
This unit is controlled by a
normally closed, air supply
shut-off valve, which requires
the pump vacuum to hold
it open. At the end of the
evacuation cycle air in the
suction line destroys the
vacuum causing the control
valve to shut off the air
pressure supply and stop
the pump. The unit also
incorporates a strainer to
prevent large particles from
damaging the pump.
AMER region
Air Units
To operate:
1. Attach the FLOCS 30A unit
quick disconnect coupling
to the mating conversion
kit coupling half on the
equipment.
2. Press the red override button
to start the unit; hold for
approximately 5 seconds.
Cycle gauge will indicate run
condition.
3. The unit will shut off
automatically when all oil
is evacuated. The cycle
gauge will indicate when the
unit is off. Disconnect the
evacuation line.
see Fig. 3. page 3.
• 15' of 1" I.D. suction
line standard.
• 5601-12-12 female coupling.
• Minimum discharge line: size 1"
I.D. (-16).
• Mounting requirements:
Installation Instructions
Mount the unit for easy
accessibility to the vehicles
to be serviced. It may be
mounted in either a horizontal
or vertical position. A mounting
bracket is provided for rigid
mounting of the pump
(reference Figure 3 for detail
dimensions). The pump motor
operates on 80-150 psi air at
5 CFM minimum. The unit is
to be mounted so that the
cycle gauge is in full view of
the operator and the override
button and strainer cleanout are
readily accessible.
1. Connect the used oil
discharge line to the 1" pipe
port at the top of the unit.
The discharge line must be
no higher than 10 feet above
FLOCS unit. It is important
to keep the discharge line
large to maintain maximum
efficiency.
Danfoss Quick Disconnect Couplings Master Catalog
Use a 1" I.D. pipe for lines 15'
to 30' long and a 1 1/4" I.D.
pipe for lines 30’ to 100’ long.
Make sure the discharge line
does not develop more head
pressure than 1/5 of the air
pressure source. (Example:
air power source of 150 psi,
discharge head pressure of 30
psi maximum.)
Figure 3
contaminating the pump
control and/or causing
freezing-up. A lubricator
is also recommended for
the air supply line (use
non-detergent oil in the
lubricator).
2. Connect the air supply line
into the 1/4" NPTF port
of the quick disconnect
coupling supplied with
the unit. The air supply
line should be equipped
with an air line water filter
to prevent water from
AF435258198969en-000102