Quick Disconnect Couplings - Flipbook - Seite 29
Danfoss Gromelle H5000 Series stainless steel quick
disconnect coupling is a pull to connect double shutoff coupling. It is a general purpose industrial coupling
with the original profile. It is mainly used in fluid transfer
applications and provides excellent corrosion resistance.
Fluid transfer & Hydraulic application
Global region
H5000 Series
(Stainless Steel)
Product Features
• Pressure performance
• Standard body material:
AISI 316L Stainless steel
• Standard seal material: FKM, EPDM
• Optional safety sleeve lock prevents
accidental disconnections
• Optional dust caps and plugs
(made of anodized aluminum)
• Proprietary pro昀椀le
• Pull-to-connect with
doubleshut-o昀昀 valving
• Ball-locking
Physical Characteristics
Max. Operating Pressure*
Body Size
(in)
¼
Nominal Flow
Diameter
Non hazardous liquids & gases Group 2
Hazardous
liquids & gases Group 1
(mm)
(bar)
(psi)
(bar)
(psi)
(lpm)
(gpm)
ml-cc.
3.8
300
4,350
300
4,350
6.1
1.61
0.4
Rated Flow**
Fluid Loss
5.7
230
3,335
230
3,335
11.6
3.06
1
7.6
175
2,535
175
2,535
16.7
4.41
2
½
10.3
150
2,175
150
2,175
25.5
6.74
2.5
¾
14.2
125
1,810
125
1,810
55
14.53
5.5
1
16.5
100
1,450
100
1,450
87
22.98
9
1¼
20.5
100
1,450
100
1,450
140
36.98
23
1½
25.8
75
1,085
28
550
208
54.95
36
2
34.7
40
580
38
405
357
94.30
70
* For pulsating pressures when disconnected apply a multiplier of 0.5
** Indicated values refer to a 1 bar/14.5 psi pressure drop.
Flow Data
Flow Rate (l/min)
10
1000
5
4
3
/2
2
2"
1"
1
1"
1
1"
3/4
1/2
1/4
1/8
29
3/8
/4
43.5
14.5
1
7.25
0.5
4.35
0.3
2.9
0.2
1.45
0.1
0.264
Group 1 = Hazardous media / Group 2 = Other media
100
72.5
58
Pressure drop (PSI)
Couplings with nominal diameters up to
and including 25 mm are designed and
manufactured under Article 4.3 of the
European Pressure Equipment Directive
PED 2014/68/EU. Couplings with nominal
diameters greater than 25 mm are
designed and manufactured in accordance
with the stipulations of Module A of the
European Pressure Equipment Directive
PED 2014/68/EU. They should not be used to
convey unstable gases.
1
Pressure drop (bar)
European Pressure Equipment Directive
2.64
26.4
264
Flow Rate (gpm)
Test Fluid: Oil viscosity 30 cSt at 40°C/104°F
Applications & Markets
• Automobile
• Agriculture
• Construction
• Oil and Gas
• Railway
• Aeronautics
• Food Processing
• Iron and Steel Industry
• Electronics
• Laboratories
• General Hydraulic
Applications
Danfoss Quick Disconnect Couplings Master Catalog
Seal Elastomer Data*
Seal Elastomer
Max. Operation Temperature Range
FKM
-20°C +200°C/-4°F +392°F
EPDM (Ethylene-Propylene)**
-40°C +150°C/-40°F +302°F
* For reference only, based on Danfoss recommended temperatures.
** In accordance with NF L 17-241 or NAS 1613 rev. 5
Contact Danfoss technical support for further information on fluid compatibility.
AF435258198969en-000102
29