Fluid transfer & Hydraulic application
EMEA region
Danfoss Hansen L7000 Series steel quick disconnect coupling is a full-flow coupling with a rugged construction. Similar to the Danfoss H5000 Series, the heat treatment and
hardened materials give the coupling excellent resistance
to mechanical and hydraulic demands. It is suited for applications where maximum flow capacity is a requirement
and valving is not needed.
L7000 Series (Steel)
Full Flow
Product Features
• Standard body material:
Zinc trivalent plated steel
• Optional dust caps and plugs
(made of anodized aluminum)
• Proprietary pro昀椀le
• Full 昀氀ow pull-to-connect couplings
• Ball-locking
• Excellent 昀氀ow performance
• Standard seal material:
NBR, FKM, EPDM
Physical Characteristics
Body
Size
Nominal Flow
Diameter
Non hazardous liquids &
gases in Group 2
(in)
(mm)
8
10
12
15
20
25
33
40
50
bar
1,000
700
600
500
400
300
200
150
100
¼
½
¾
1
1¼
1½
2
European Pressure Equipment
Directive*
Couplings with nominal diameters up to
and including 25 mm are designed and
manufactured under Article 4.3 of the European Pressure Equipment Directive PED
2014/68/EU. Couplings with nominal
diameters greater than 25 mm are designed
and manufactured in accordance with the
stipulations of Module A of the European
Pressure Equipment Directive PED 2014/68/
EU. They should not be used to convey
unstable gases.
Max. Operating Pressure (connected)*
Hazardous liquids &
gases in Group 1
(psi)
14,500
10,150
8,700
7,250
5,800
4,350
2,900
2,175
1,450
bar
1,000
700
600
500
400
300
30
24
19
(psi)
14,500
10,150
8,700
7,250
5,800
4,350
435
345
275
Flow Data
The nominal flow diameter of the coupling has no impact on pressure drop, as
it is wider than the circuit diameter.
Seal Elastomer Data*
Seal Elastomer
Max. Operation Temperature Range
NBR (Nitrile)
FKM (Fluorocarbon)
EPDM (Ethylene-Propylene)**
-20°C +100°C/-4°F +212°F
-20°C +200°C/-4°F +392°F
-40°C +150°C/-40°F +302°F
*For reference only, based on Danfoss recommended temperatures.
**In accordance with NF L 17-241 or NAS 1613 rev. 5, depending on size.
Contact Danfoss technical support for further information on fluid compatibility.
*Group 1 = Hazardous media / Group 2 = Other media
Applications & Markets
• Fluid Transfer Lines
• Refrigerant Circuits
• Applications where
maximum flow capacity
is required
Danfoss Quick Disconnect Couplings Master Catalog
AF435258198969en-000102
52