Quick Disconnect Couplings - Flipbook - Seite 55
Fluid transfer & Hydraulic application
Danfoss' L7000 Series brass quick disconnect coupling
is a full-flow coupling suited for applications where
maximum flow capacity is required and valving is not
needed. Mainly used in fluid transfer applications where
stainless steel is not a requirement, it can vehicle a wide
range of media and offers good corrosion resistance.
EMEA region
L7000 Series (Brass)
Full Flow
Product Features
• Standard body material:
Nickel-plated brass
• Optional dust caps and plugs
(made of anodized aluminum)
• Proprietary pro昀椀le
• Full 昀氀ow pull-to-connect couplings
• Ball-locking
• Excellent 昀氀ow performance
• Standard seal material:
NBR, FKM, EPDM
Physical Characteristics
Max. Operating Pressure (connected)*
Body
Size
Nominal Flow
Diameter
Liquids in Groups 1 and 2
Gases in Group 2
(in)
(mm)
8
10
12
15
20
25
33
40
50
bar
300
230
175
150
125
100
60
49
39
bar
300
230
175
150
125
100
30
24
19
¼
½
¾
1
1¼
1½
2
(psi)
4,350
3,335
2,535
2,175
1,810
1,450
870
710
565
(psi)
4,350
3,335
2,535
2,175
1,810
1,450
435
348
275
*Nominal diameters over 25 mm should not be used to convey gases in Group 1
(as per PED 2014/68/EU).
European Pressure Equipment
Directive*
All couplings are designed and manufactured
under Article 4.3 of the European Pressure
Equipment Directive PED 2014/68/EU.
Couplings with nominal diameters greater
than 25 mm should not be used to convey
gases in Group 1 (hazardous).
* Group 1 = Hazardous media / Group 2 = Other media
Applications & Markets
• Pressure Washing
• Steam-Cleaning Equipment
• Fluid Transfer Lines
• Refrigerant Circuits
• Applications where
maximum flow capacity
is required
Danfoss Quick Disconnect Couplings Master Catalog
Flow Data
The nominal flow diameter of the coupling has no impact on pressure drop,
as it is wider than the circuit diameter.
Seal Elastomer Data*
Seal Elastomer
Max. Operation Temperature Range
NBR (Nitrile)
FKM (Fluorocarbon)
EPDM (Ethylene-Propylene)**
-20°C +100°C/-4°F +212°F
-20°C +200°C/-4°F +392°F
-40°C +150°C/-40°F +302°F
*For reference only, based on Danfoss recommended temperatures.
**In accordance with NF L 17-241 or NAS 1613 rev. 5, depending on size.
Contact Danfoss technical support for further information on fluid compatibility.
AF435258198969en-000102