Quick Disconnect Couplings - Flipbook - Seite 73
Fluid transfer & Hydraulic application
Product Features
• Dual flush face valving for minimal fluid
loss and air inclusion
• Tubular valve and sleeve construction
for high fluid flow with low pressure
drop
Danfoss Hansen FD49 Series meets NFPA standard
T3.20.15 and was developed in conjunction with HTMA
(Hydraulic Tool Manufacturer’s Association). Danfoss’
Twin-Guard™ sealing system prevents weepage at low
pressures and allows connection and disconnection
against pressure up to 500 psi.
AMER region
FD49 Series
NFPA Standard T3.20.15 HTMA
Interchange
• Standard body material: High resistance
carbon steel with zinc trivalent plating
• Push-to-connect latching for one hand
operation
• Standard seal material: Teflon channel
seal and Buna-N O-Ring backup
Physical Characteristics
Body
Size
Max. Operating
Pressure
Min. Burst Pressure
Connected
Vacuum
Connected Only
Rated
Flow
Air
Inclusion
Fluid
Loss
(in)
3/8
(bar)
207
(bar) (psi)
621
9,000
(in./Hg)
28
(lpm) (gpm)
38
10
cc. max.
.01
cc.max.
.02
(psi)
3,000
Danfoss’ Twin-Guard™ seal system consists of channel and Buna-N O-Ring
seals. The channel seal prevents blowout during connection and
disconnection under pressure to 500 psi. TheBuna-N O-Ring seal is a
secondary seal eliminating fluid weepage.
Flow Data
Pressure Drop Versus Flow Graph
gpm
2.64
5.28
7.92
10.56
15.84
21.12
58
3
43.5
2
29
1
14.5
3/8
0.5
7.25
0.1
0.05
psi
1.056
4
Pressure Drop,
bar
bar
Applications & Markets
• Hydraulic tool (HTMA
interchange)
• Hydraulic and fluid transfer
1.45
4
6
8
10
12
16
20
30
40
60
0.725
80
lpm
Gallons Per Minute Flow
Test Fluid: MIL-H-5606 Oil at 100°F
Danfoss Quick Disconnect Couplings Master Catalog
AF435258198969en-000102
73